Read or Download Accid. Anal. - Nuclear Powerplants with PHWRs PDF

Similar nuclear books

Principles of Fusion Energy

This textbook contains the 2 divergent developmental paths that have develop into solidly proven within the box of fusion power: the method of sequential tokamak improvement towards a prototype and the necessity for a extra primary and integrative study procedure sooner than expensive layout offerings are made.

America's Cold War: The Politics of Insecurity

The chilly battle ruled international affairs throughout the part century following international battle II. It led to victory for the U.S., but it was once a expensive triumph, claiming trillions of bucks in protection spending and the lives of approximately 100,000 U. S. squaddies. Apocalyptic anti-communism sharply constrained the variety of applicable political debate, whereas American activities abroad resulted in the dying of hundreds of thousands of blameless civilians and destabilized dozens of countries that posed no possibility to the us.

Advances in Nuclear Physics: Volume 1

The purpose of Advances in Nuclear Physics is to supply assessment papers which chart the sector of nuclear physics with a few regularity and completeness. We outline the sphere of nuclear physics as that which offers with the constitution and behaviour of atomic nuclei. even supposing many solid books and experiences on nuclear physics can be found, none makes an attempt to supply a assurance that's even as carrying on with and fairly whole.

Additional info for Accid. Anal. - Nuclear Powerplants with PHWRs

Sample text

Atomic Energy Control Board Consultative Document C-006. calandria. Low pressure vessel containing the heavy water moderator, through which the fuel channels run. calandria tube. Zircaloy tube surrounding the pressure tube for each channel, separated from it by a small insulating gas gap. channel. Fuel channel consisting of a pressure tube and its surrounding calandria tube. Class III power. Diesel generated emergency electric power. There are two independent and widely separated sets of Class III diesels: Group 1 diesels and Group 2 diesels.

Class IV power. Normal AC electric power from the grid or from the turbine generator via the unit service transformer. core pass. Transit of fluid once through the core via a pump and a steam generator. e. fluid goes through the core twice before returning to its starting point). The loop in which a LOCA is assumed to have occurred is called the broken loop; the other loop is called the intact loop. crash cooldown. Rapid cooldown of the steam generator secondary side through the main steam safety valves; activated on a LOCA signal.

The latter are seismically qualified. Class IV power. Normal AC electric power from the grid or from the turbine generator via the unit service transformer. core pass. Transit of fluid once through the core via a pump and a steam generator. e. fluid goes through the core twice before returning to its starting point). The loop in which a LOCA is assumed to have occurred is called the broken loop; the other loop is called the intact loop. crash cooldown. Rapid cooldown of the steam generator secondary side through the main steam safety valves; activated on a LOCA signal.